Precision Engineering Service
Custom Size & Mold
Engineering
Turnkey ceramic filter plate customization for non-standard equipment and special slurry conditions -- led by 6 senior ceramic engineers. From CAD drawing import or worn-sample reverse engineering to proprietary mold development, precision forming and high-temperature sintering: every step under one roof.
- Engineering Team
- 6 Specialists
- Pore Range
- 1.2-5.0 µm
- Input Methods
- 3 Pathways
- Mold From
- Drawing / Sample
When Standard Plates Fall Short
Non-standard equipment deserves a purpose-built solution.
Aging or discontinued filter machines, imported equipment without spare-part supply, self-fabricated processing lines -- all present dimensional and process challenges that off-the-shelf plates cannot solve. Our mold engineering team closes that gap through dimensional reverse engineering, materials science and proprietary forming technology.
- Discontinued OEM plates -- reverse-engineered from your worn sample with full dimensional replication and pore-structure matching.
- Imported or legacy equipment -- adapted plates manufactured to match foreign drawing standards, tolerances and nozzle fittings.
- Special slurry conditions -- micropore diameter in the 1.2-5.0 µm range formulated to your mineral type, particle size distribution and target moisture.
- Non-standard flow channels & nozzles -- 80% flat-channel low-resistance architecture adapted to stainless flanges, threaded fittings or quick-insert nylon connectors.

Three Input Pathways
Multi-pathway reverse engineering -- start from what you have.
Whether you hold a digital drawing, a worn physical plate or only on-site machine measurements, our engineering team has a defined intake pathway to convert your data into a precision mold and production-ready ceramic plate.
CAD Drawing Import
Client provides digital drawings in DWG, DXF or STEP format. Our engineers import files directly into CNC toolpath generation and mold design software -- eliminating manual re-measurement and minimising dimensional transcription error.
- Accepts DWG / DXF / STEP / IGES
- Fastest pathway -- drawing-to-mold in shortest lead time
- Tolerance review and engineering confirmation issued within 48 h
Physical Sample 3D Scanning
Ship a worn or intact plate -- or a non-standard nozzle fitting -- to our facility. Our engineers perform high-resolution 3D scanning and reverse-CAD reconstruction, capturing all surface geometry, channel profiles and mounting features even on heavily worn samples.
- Full-surface point-cloud capture and mesh reconstruction
- Dimensional restoration of worn geometry to original spec
- Nozzle and fitting profiles replicated from physical sample
- Reconstructed DXF/STEP returned to client for confirmation
On-Site Dimensional Survey
No sample or drawing available? Provide your main-shaft flange dimensions, disc outer diameter and sector subtended angle measured on-site. Our engineers use these field measurements to complete a matched plate design and issue a confirmation drawing for your approval before tooling begins.
- Shaft flange OD / ID / bolt-circle / key-slot dimensions
- Disc outer diameter and sector arc angle
- Plate thickness and nozzle position / type noted
- Measurement guide sheet provided by our team on request
CAD Drawing
DWG / DXF / STEP → direct CNC import
Physical Sample
3D scan → reverse CAD reconstruction
On-Site Survey
Flange + disc measurements → matched design

80% Flat-Channel
Low flow-resistance architecture
3 Nozzle Types
Flange · Thread · Quick-insert
Flow Channel & Nozzle Engineering
Proprietary flat-channel architecture, adapted to your machine interface.
All custom plates retain our core 80% flat-channel low-resistance flow architecture -- maintaining high filtrate throughput and minimising internal pressure drop. The nozzle interface is then re-engineered to match your specific machine connection standard.
Why 80% flat-channel?
Conventional round-channel designs restrict cross-sectional flow area. Our flat-channel geometry increases effective flow cross-section to 80% of plate body width, reducing internal resistance, accelerating filtrate drainage and extending plate service life by reducing localised stress concentration.
Available nozzle interface types
Stainless Steel Flange
Bolt-on flange connection; suits high-pressure and heavy-duty vacuum systems.
Threaded Fitting
Stainless or engineering-plastic threaded insert; compatible with standard pipe connections.
Quick-Insert Nylon
Push-fit nylon connector for rapid on-site plate replacement; corrosion-resistant.
Nozzle geometry -- including thread pitch, outer diameter, insertion depth and seal groove -- is re-machined to match your existing manifold or valve-block interface, ensuring a drop-in fit with zero site modification.
Micropore Diameter Customization
1.2-5.0 µm pore range, formulated to your slurry.
Micropore diameter is the single most critical variable governing filtration rate, filter cake moisture content and the risk of fine-particle bleed-through. Our materials laboratory directionally formulates and fires alumina slurry to achieve a target pore diameter anywhere in the 1.2 µm to 5.0 µm range, balancing permeate flux against particle retention for your specific ore and process conditions.
1.2-2.0 µm Fine
2.0-3.0 µm Medium
3.0-4.0 µm Standard
4.0-5.0 µm
How we select your pore spec
- Ultra-fine / high-viscosity slurry (d80 < 20 µm) -- specify 1.2-2.0 µm to prevent fine-particle migration and achieve lowest cake moisture.
- Standard concentrate (d80 20-75 µm) -- 2.0-3.5 µm balances permeate flux with adequate particle retention for most mineral concentrates.
- Coarse particle / tailings (d80 > 75 µm) -- 3.5-5.0 µm delivers higher throughput flow rate for large-volume dewatering with coarser particle distribution.
- Acid / alkali slurry -- pH value is incorporated into formulation selection; chemically resistant alumina grade specified at batch level.
Highest particle retention
Engineered for ultra-fine mineral powders and high-viscosity slurries where preventing fine-particle bleed-through is critical.
Typical applications:
Lithium spodumene, ultra-fine iron ore concentrate, high-clay slurry
Balanced flux & retention
Optimal for most mineral concentrates -- balances filtration rate with low cake moisture and reliable particle retention.
Typical applications:
Copper sulfide, gold concentrate, nickel laterite
Higher throughput
Suited to mixed-grade or moderately coarse particle distributions where throughput capacity takes priority over minimum moisture.
Typical applications:
Lead & zinc mixed concentrate, tailings dewatering
Maximum flow rate
Maximum permeate flux for coarse-particle, high-volume slurry dewatering where throughput is the primary constraint.
Typical applications:
Coarse iron ore tailings, high-volume mine dewatering
Intermediate or non-standard pore specification?
Our materials laboratory can develop any target pore diameter within the 1.2-5.0 µm range based on your particle size analysis report (PSA), slurry rheology data and target cake moisture. Provide your process data and we will propose a formulation and conduct a pilot-batch verification before bulk production.
Quick-reference: pore diameter vs. particle distribution
| Slurry d80 | Recommended pore | Primary benefit |
|---|---|---|
| < 20 µm (ultra-fine) | 1.2-2.0 µm | Lowest moisture, zero bleed-through |
| 20-75 µm (standard) | 2.0-3.5 µm | Balanced flux & retention |
| 75-150 µm (coarse) | 3.5-5.0 µm | High throughput, rapid dewatering |
| Mixed / variable | Lab-determined | PSA-based formulation by materials team |
Full-Process Delivery Timeline
From specification intake to certified delivery -- every step in-house.
Our integrated facility handles dimensional capture, mold tooling, body forming and kiln sintering under one roof -- eliminating handover errors and compressing lead times. Below is the full-process timeline for a standard custom mold order.
Day 1-2
Specification Intake & Review
Client submits drawings (DWG/DXF/STEP), physical samples or on-site measurement data. Engineering team reviews dimensional completeness, identifies tolerance requirements and confirms pore grade, nozzle interface type and order quantity. Written confirmation and dimensional clarification issued within 48 business hours.
Day 3-7
3D Survey / CAD Reconstruction
For sample-based orders: high-resolution 3D scanning and reverse CAD reconstruction completed; DXF/STEP confirmation drawing issued to client for sign-off. For drawing-based orders: direct import and tolerance verification. For site-survey orders: matched plate design completed from provided measurements. Client approval required before proceeding to mold tooling.
Day 8-18
Mold Design & Tooling Fabrication
Proprietary mold tooling fabricated in-house to matched plate geometry. Flow-channel profile -- including 80% flat-channel architecture -- and nozzle interface geometry (flange / threaded / quick-insert) machined to specification. Mold dimensional verification performed before release to forming line.
Day 19-25
Alumina Formulation & Body Forming
Alumina slurry batch formulated to target pore diameter (1.2-5.0 µm range) based on confirmed pore specification and chemical resistance requirement. Advanced water-casting process used for integral body forming -- eliminating lamination defects and ensuring uniform pore distribution across the full plate cross-section. Green-body dimensional check performed per batch.
Day 26-35
High-Temperature Sintering
Whole-body sintering in tunnel kilns under controlled atmosphere and temperature profile. Sintering parameters are optimised for target bulk density, compressive strength and micropore diameter. Kiln curve data logged per batch for quality traceability. Post-sintering dimensional check and surface inspection performed before QC laboratory testing.
Day 36-40
QC Testing & Certified Delivery
On-site physicochemical laboratory performs: pore size distribution analysis, compressive strength test, water absorption measurement, surface flatness and dimensional verification. Plates meeting specification are packaged in protective export crating. Full batch test certificate issued and shipped with order. Pre-production sample batch available for client approval before bulk shipment on request.
New Mold Order
35-45 days
First article from drawing or sample to delivery
Repeat Order (existing mold)
15-20 days
Mold already tooled; forming and sintering only
Sample Approval Batch
On request
Pre-production sample batch before bulk manufacturing

In-house kiln facility
High-temperature sintering kilns -- full thermal process control.
Manufacturing Credentials
Built for volume. Verified for quality.
Government-designated advanced materials enterprise with standardized production lines and planned capacity of 400,000 plates per year.
Collaborative research with Shandong University of Technology's New Materials Laboratory on microporous alumina formulation and pore engineering.
Proprietary forming and water-casting process patents covering custom mold development and directional pore engineering.
On-site lab for pore size distribution, compressive strength, water absorption and surface quality verification per batch.
Start Your Custom Order
What to prepare before you contact us.
Providing complete specifications upfront eliminates back-and-forth and lets our engineers issue an accurate proposal within 48 hours. Use this checklist to gather the key data points.
Filter Machine Model & Existing Plate Dimensions
Machine brand, model number and current plate outer diameter / thickness. Include photos of the worn plate showing key surfaces, flow channels and mounting geometry if available. Alternatively, provide on-site measurements of main-shaft flange, disc diameter and sector angle.
Nozzle / Flow-Channel Interface Type
Specify existing nozzle connection type: stainless steel flange, threaded fitting or quick-insert nylon connector. If unknown, provide photos or dimensions of the existing manifold connection point and our team will identify the correct interface.
Filtration Area & Plates per Disc
Single-plate effective filtration area (m²) and the number of plates installed per disc (standard configuration is typically 12 plates per disc).
Mineral & Slurry Process Parameters
Ore type, slurry solids concentration (%), particle size distribution (d50 / d80 or full PSA curve), pH value and target filter cake moisture content (%). This data directly determines the optimal pore diameter in the 1.2-5.0 µm range.
Target Micropore Diameter
Specify a target pore range within 1.2-5.0 µm. If unsure, share your particle size analysis data and our materials laboratory will recommend the optimal formulation. Ultra-fine slurries typically require 1.2-2.0 µm; coarse tailings typically 3.5-5.0 µm.
Chemical Resistance Requirements
Indicate whether the slurry is acidic or alkaline. If acid or alkali washing is part of your operating cycle, specify solution type and concentration for material grade selection.
Order Quantity & Delivery Requirements
Total number of plates required, any phased delivery schedule and destination port or site address for logistics planning.
Custom Plate Inquiry
Send us your specifications
Our engineers respond within 48 business hours.
Custom plates in operation
Proven across mineral processing applications.
Iron Ore
Concentrate dewatering
Copper
Sulfide concentrate
Gold
CIL tailings
Lithium
Spodumene / brines
Nickel
Laterite & sulfide
Lead & Zinc
Mixed concentrate
NDA Available
All technical drawings and process data treated as confidential. Non-disclosure agreement provided on request before any data transfer.
Sample Approval
Pre-production sample batch provided for dimensional and functional verification before bulk manufacturing begins. Test certificate included.
Global Delivery
Export packaging with full dimensional and physicochemical test certificates. Experienced with CIF, FOB and door-to-site logistics for mining operations worldwide.